3.1 Mapping peroxide torsion with a relaxed scan
These are unexecuted teaching inputs and starting models. Original diagrams are schematics, not calculated results. Validate version-specific syntax, licensed or authorized data, numerical convergence and the scientific model before using this workflow.
3.1.1 Model, units and provenance
Geometry in Å; electronic energy in hartree; vibrational wavenumbers in cm⁻¹. Check each printed field and keep thermal and standard-state terms distinct.
Shared inputs, conventions and evidence
3.1.2 Unexecuted inputs and explicit deltas
Use the accompanying instructions to identify the parent calculation and placement of every delta; a snippet is not automatically a standalone input. Preserve all blank-line and file-provenance requirements.
3.1.2.1 Input block 1
%chk=case09_peroxide_scan.chk
%mem=4GB
%nprocshared=2
#p B3LYP/6-31G(d) Opt=(ModRedundant,Tight,CalcFC,MaxCycle=100)
SCF=Tight Integral=UltraFine NoSymm
Peroxide relaxed torsion scan with original starting geometry
0 1
O 0.000000 0.000000 0.000000
O 1.450000 0.000000 0.000000
H -0.250000 0.930000 0.000000
H 1.700000 0.000000 0.930000
D 3 1 2 4 S 36 10.0
3.1.3 Worked investigation
3.1.3.1 Question and intuition
How does a molecule's energy change when one bond rotates while the rest of its geometry is allowed to adapt? Hydrogen peroxide provides a compact answer: its H–O–O–H dihedral changes without changing connectivity. Think of holding a door at a series of angles while allowing its flexible frame to settle. A relaxed scan fixes the chosen torsion at each target and optimizes the remaining coordinates. A rigid scan instead leaves the other coordinates unchanged. Their curves answer different questions, so neither should be silently relabeled as the other.
Prerequisites are atom numbering, charge/multiplicity, one ordinary geometry optimization, and the distinction between an input geometry and a converged structure. This example has neutral singlet H2O2. Atoms 1 and 2 are oxygen, atoms 3 and 4 are hydrogen, so the torsion is D(3,1,2,4). Keep this ordering in later files. A gas-phase peroxide profile is qualitatively expected to favor a nonplanar conformation over at least some planar orientations, but neither the precise minimum angle nor the barrier is supplied here as a computed result.
3.1.3.2 Complete input
See input block 1 above.
The final line requests 36 increments of 10 degrees from the initial dihedral, with constrained relaxation at the scan points. Do not assume a plotting program's displayed point count from the input integer alone: inspect the actual completed scan table and determine whether the starting point is included. The starting geometry is already near a 90-degree torsion by this atom definition, so the scan is not necessarily displayed as 0, 10, 20 degrees. NoSymm avoids unwanted symmetry restrictions during the rotation. CalcFC builds an initial Hessian; it does not turn every scan point into a frequency calculation.
3.1.3.3 Workflow
- Open the starting geometry, display atom numbers, and measure D(3,1,2,4). Confirm O–O and O–H connectivity before launching the scan.
- Run the job and inspect convergence at every constrained point. A final normal termination alone is not a substitute for checking whether the requested scan actually completed. Keep the original output rather than retaining only a screenshot of the curve.
- Extract each completed point's torsion, electronic energy, and optimized coordinates. Convert all angles to one consistent interval, or unwrap them continuously. Do not sort wrapped angles without moving their matching energies and structures together.
- Plot ΔE(φ) = [E(φ) − Emin] × 2625.4996 in kJ mol−1, with φ in degrees. The energies supplied by Gaussian are in hartree. If you use kcal mol−1 instead, multiply the hartree difference by 627.5095 and label the axis accordingly.
- Export a low-energy scan structure into a new, unconstrained Opt Freq input at exactly the same level; remove Opt=ModRedundant and the scan line. Export coordinates explicitly, because the scan checkpoint commonly represents a recent/final scan geometry, not the lowest-energy point you happen to select in a viewer.
- Refine an interesting region with a smaller angular increment and compare a reverse-direction scan if the profile has jumps. Agreement between independent approaches is more convincing than a visually smooth line.
3.1.3.4 Interpretation checks and pitfalls
A scan point is stationary only with respect to its allowed coordinates. It is therefore not automatically a minimum or a transition state on the full potential-energy surface. Likewise, the highest sampled point is merely the largest energy among the sampled constraints; it is a possible transition-state guess, not a validated barrier structure. Duplicate conformations at the periodic endpoints should not be counted twice in a conformer population. An apparent discontinuity can arise from angle wrapping, a different local conformer, or failed optimization; distinguish these by inspecting the structures.
The deliverable is a data-backed torsion curve, a convergence flag for each point, and at least one freely reoptimized minimum with its frequency check. Qualitative prediction: reversing the scan should reproduce the same physical profile for this small system when convergence is good, allowing for periodic reindexing. Do not report this expectation as an observed result before running it.
3.1.4 Related calculations
- 2.4 Optimize a water molecule and read all four criteria
- 3.2 Proving that an optimized water structure is a minimum