Skip to content

2.3 Aluminum metal: occupations and the Fermi surface

These are unexecuted teaching inputs and starting models. Original diagrams are schematics, not calculated results. Validate version-specific syntax, licensed or authorized data, numerical convergence and the scientific model before using this workflow.

2.3.1 Model, units and provenance

PW cutoffs and energies use Ry, common force output uses Ry/bohr, and pressure uses kbar. Geometry cards state their coordinate units. Different executables have distinct grammars and time-unit conventions.

Shared inputs, conventions and evidence

Original schematic: Aluminum metal: occupations and the Fermi surface. No numerical results are claimed.
Original schematic: Aluminum metal: occupations and the Fermi surface. No numerical results are claimed.

2.3.2 Unexecuted inputs and explicit deltas

Use the accompanying instructions to identify the parent calculation and placement of every delta; a snippet is not automatically a standalone input. Preserve all blank-line and file-provenance requirements.

2.3.2.1 Input block 1

&CONTROL
 calculation='scf', prefix='al', pseudo_dir='./pseudo', outdir='./scratch/al',
 tstress=.true., tprnfor=.true.
/
&SYSTEM
 ibrav=2, A=4.05, nat=1, ntyp=1, ecutwfc=60, ecutrho=480,
 occupations='smearing', smearing='mv', degauss=0.02
/
&ELECTRONS
 conv_thr=1.0d-10, mixing_beta=0.3
/
ATOMIC_SPECIES
Al 26.9815385 Al.PBE.UPF
ATOMIC_POSITIONS crystal
Al 0.0 0.0 0.0
K_POINTS automatic
12 12 12 0 0 0

2.3.3 Worked investigation

2.3.3.1 Intuition and prerequisites

Metallic occupations change rapidly near the Fermi surface. Smearing helps integrate and converge them, but a broadening parameter is not permission to neglect k sampling. Start from a verified PBE Al pseudopotential. The 4.05 Å lattice is an initial geometry. This case creates “Al-base” for later slabs and tests the coupled dependence on mesh and smearing.

2.3.3.2 Complete original template

See input block 1 above.

2.3.3.3 Checks, pitfalls and exercise

Check that enough empty bands are present and the highest included band is negligibly occupied. Track pressure as well as energy: a visually flat energy curve can coexist with inadequate stress accuracy. Keep mesh parity and offsets consistent when comparing sequences. Exercise: choose the least expensive mesh/width combination meeting a declared energy-per-atom and pressure tolerance, then validate it against a denser mesh with smaller width. Report the failed combinations too.

2.3.5 Sources and further reading