Skip to content

6.4 Quasiharmonic thermal expansion

These are unexecuted teaching inputs and starting settings to test. Original figures are schematics, not computed results. Use licensed VASP and PAW data, replace every placeholder, record the executable version and validate convergence.

6.4.1 Model, units and provenance

Use eV for energy, Å for length and eV/Å for force; 1 kbar = 0.1 GPa. State normalization per atom, molecule, primitive cell or simulation cell. Record PAW identifiers, release, ZVAL, ENMAX and permitted hashes; never redistribute POTCAR. SCF convergence addresses the chosen electronic problem; convergence of the target property requires separate tests.

 Quasiharmonic thermal expansion — original conceptual schematic

Original schematic. Curves explain concepts; blank data areas await verified learner results. No calculation is claimed.

\[ G(T,P)=\min_V\left[E_{\mathrm{static}}(V)+F_{\mathrm{vib}}(V,T)+PV\right],\quad\alpha_V=\frac1V\left(\frac{\partial V}{\partial T}\right)_P,\quad C_P-C_V=TV\alpha_V^2B_T \]

6.4.2 Worked case: procedure, interpretation and checks

The key extra variable

A strictly harmonic calculation at one volume has no volume degree of freedom and cannot predict thermal expansion by itself. In the quasiharmonic approximation (QHA), each volume has its own harmonic spectrum. The equilibrium volume shifts because the sum of electronic and vibrational free energy changes shape with temperature:

G(T,p) = minV [Estatic(V)+Fvib(V,T)+pV].

Define volumetric expansion αV=(1/V)(∂V/∂T)p, with units K⁻¹. For an isotropically expanding cubic crystal, linear αL=αV/3. This relation must not be assumed for general anisotropic crystals. The isothermal bulk modulus is BT=V(∂²F/∂V²)T at the relevant equilibrium volume.

Work plan and data contract

QHA is an entire family of phonon calculations, not one additional INCAR flag. Build on 5.1 Equation of state and bulk modulus and 6.3 Harmonic free energy, heat capacity, and entropy.

  1. Choose a volume grid that covers the expected free-energy minima at all target temperatures. Use more than the mathematical minimum of points and inspect interpolation quality.
  2. At each volume relax internal coordinates under the same structural constraints, then compute its static energy and phonon force constants. Keep chemical composition, physical model, masses, primitive mapping, and electronic accuracy consistent.
  3. Compute Fvib, Svib, and Cv at every volume on exactly the same temperature grid and similarly converged q meshes. Inspect stability at each volume; an unstable expanded cell cannot simply be kept with its imaginary modes omitted.
  4. Create e-v.dat with volume in ų and static energy in eV for the same primitive-cell normalization as the thermal files. A supercell total energy accidentally paired with primitive-cell phonon free energy is a severe normalization error.
  5. Supply the thermal files in the same order as the energy-volume rows. Prefer an explicit manifest sorted by actual numeric volume over a wildcard whose lexical ordering may be misleading.
  6. Fit the free-energy curve at each temperature, extract V(T), then differentiate carefully. Plot each fitted minimum relative to the sampled interval. If the minimum leaves the interval, extend the physical calculation set rather than trusting extrapolation.

Generate thermal data at least one temperature step beyond the maximum derivative-based output temperature as required by the installed interface. Do not apply pV twice: use either a correctly configured pressure option or explicitly incorporated pressure work, following the program's conventions. Convert GPa×ų to eV before manual arithmetic. Nonzero-pressure outputs and derivative conventions should be checked against the specific release documentation; the current Phonopy QHA page flags limitations in some pressure-dependent bulk-modulus outputs.

Understanding the result

A useful microscopic quantity is mode Grüneisen parameter γλ=−∂lnωλ/∂lnV. Modes that soften as volume grows have positive γ and often favor expansion. Some modes may have negative γ and contribute to negative thermal expansion. This does not mean every negative-expansion material can be understood with an isotropic volume-only model.

Cp−Cv = T V αV² BT when quantities use consistent extensive units and the usual thermodynamic conditions. Thus comparing measured Cp directly with fixed-volume lattice Cv can create an avoidable discrepancy. Numerical differentiation magnifies noise: jagged αV(T) can come from tiny inconsistent E(V) offsets or underconverged phonons even when V(T) appears smooth.

QHA includes frequency changes caused by volume, but not explicit temperature-dependent anharmonic renormalization at fixed volume, melting, diffusion, configurational disorder, or magnetic transitions. Near soft-mode transitions or high temperatures, use a more appropriate anharmonic treatment rather than extending the curve mechanically.

Exercise

6.4.3 Unexecuted inputs and analysis scaffolds

These are unexecuted teaching inputs and starting settings to test. Original figures are schematics, not computed results. Use licensed VASP and PAW data, replace every placeholder, record the executable version and validate convergence.

6.4.3.1 Input block 1

# External QHA command pattern, after all VASP/phonon jobs are validated
phonopy-qha e-v.dat thermal_V01.yaml thermal_V02.yaml thermal_V03.yaml thermal_V04.yaml thermal_V05.yaml
# Supply more files when your validated volume grid contains more points.
# File order must match e-v.dat. The names do not encode a guaranteed volume.

6.4.5 Technical sources