Skip to content

2.2 General basis input and ECP bookkeeping

These are unexecuted teaching inputs and starting models. Original diagrams are schematics, not calculated results. Validate version-specific syntax, licensed or authorized data, numerical convergence and the scientific model before using this workflow.

2.2.1 Model, units and provenance

Geometry in Å; electronic energy in hartree; vibrational wavenumbers in cm⁻¹. Check each printed field and keep thermal and standard-state terms distinct.

Shared inputs, conventions and evidence

Original schematic: General basis input and ECP bookkeeping. No numerical results are claimed.
Original schematic: General basis input and ECP bookkeeping. No numerical results are claimed.

2.2.2 Unexecuted inputs and explicit deltas

Use the accompanying instructions to identify the parent calculation and placement of every delta; a snippet is not automatically a standalone input. Preserve all blank-line and file-provenance requirements.

2.2.2.1 Input block 1

%chk=g06_water_gen.chk
%mem=2GB
%nprocshared=2
#p HF/Gen SP SCF=Tight

Water general basis using built in definitions

0 1
O  0.000000  0.000000  0.000000
H  0.758000  0.000000  0.586000
H -0.758000  0.000000  0.586000

O 0
6-31G(d)
****
H 0
6-31G
****

2.2.2.2 Input block 2

%chk=g06_hbr_ecp.chk
%mem=2GB
%nprocshared=2
#p HF/GenECP SP SCF=Tight

HBr basis and effective core potential bookkeeping

0 1
Br 0.000000 0.000000 0.000000
H  0.000000 0.000000 1.420000

H 0
6-31G
****
Br 0
LANL2DZ
****

Br 0
LANL2DZ

2.2.3 Worked investigation

2.2.3.1 Intuition and prerequisites

Built-in basis names are convenient, but a real project may mix basis quality across elements or use an effective core potential. The key distinction is that orbital basis functions describe the explicitly treated electrons, while an ECP replaces a selected core interaction. An ECP block is not another orbital basis block. Begin with an all-electron Gen water job, then examine a compact bromine-containing example. The aim is input literacy and electron bookkeeping, not an endorsement of an older small ECP basis for modern quantitative work.

See input block 1 above.

An independent ECP syntax experiment, coordinates in Å:

See input block 2 above.

2.2.3.2 Workflow

  1. Confirm that each element appears in exactly the intended orbital-basis assignment. The zero ends the center-selection line; **** ends each basis block.
  2. Run water and compare with a built-in HF/6-31G(d) job. Because H uses 6-31G and heavy-atom d polarization applies to O, these specifications should describe the same intended basis.
  3. Inspect HBr's basis and pseudopotential summary, including how many Br core electrons were replaced. Compute the explicitly treated electron number from the printed ECP definition.
  4. Verify that the ECP is applied to Br alone, that total physical charge remains zero, and that the calculation is a singlet.
  5. Before any chemical comparison, select and document a compatible modern basis/ECP family for the target property; never combine unrelated ECP and orbital-basis names by appearance alone.

2.2.3.3 Interpret check and limits

The all-electron nuclear-charge sum and the explicitly treated electron count differ in an ECP calculation. This is expected and must not be “corrected” by changing the molecular charge. A parser error after coordinates often means a missing blank line or basis terminator, not an SCF problem. Using GenECP without an ECP section for the intended heavy atom does not constitute a valid pseudopotential specification. Relativistic treatment and core size affect properties; small valence bases can remain limiting even with a sensible ECP. Core-sensitive spectroscopy needs special care beyond this tutorial.

Exercise Annotate the HBr file line by line, then explain how you would verify a downloaded basis/ECP pair without publishing restricted software assets.

2.2.5 Sources and further reading